简介:AIM:Todefinetheultrasonographicstructureofnormallowereyelidanatomiccompartmentsandtheirspacialrelationshipindynamicmotion.METHODS:Highresolutionultrasound(15MHz)wasperformedonthelowereyelidsof7normalsubjects.Movementsofthelowereyelidanditscompartmentswerevisualizedwithultrasound.Inaddition,themaximalexcursionareaofthelowereyelidfatcompartmentsandretractormotionswasmeasuredbeforeandaftermotion.RESULTS:Theorbicularismusclecouldbeseenasanecholucentstructurebetweenthedermisandtheechodencefatpads.Lowereyelidfatpadseemstobedividedinto2compartmentsasrangeofmotionanddirectionofmovementofeachofthemvaries.Itseemsthatthesecompartmentshavealsodifferentbehavior.Themeasuredprofileareaofthevisiblenormallowereyelidfatpadsduringmovementofglobefromup-gazetodown-gazedecreasedby50%.Orderofmovementoflowereyelidstructuresseemstobeasfollows:afterglobemovementfistweseeretractormovement,anteriororbitalfatpad,thenskinandseptum,andfinallymovementofinferiorfatpad.CONCLUSION:Ultrasoundrepresentsanoninvasivetoolforthevisualizationoflowereyelidmorphology.Expandingitsapplicationcouldhelpusunderstandthecompartmentalchangesinphysiologicaleyelidmovement,inaginganddiseasedstudypopulations,aswellasassessoperativeoutcomes.
简介:目的探讨一种规范化的的高度近视白内障超声乳化方式,总结手术注意点。方法选取高度近视白内障患者91例(91眼)均予以超声乳化联合人工晶体植入术治疗并总结。结果所有病例的术后裸眼视力均优于术前裸眼视力。术后第1天裸眼视力≥0.2共72眼(79.12%),≥0.5共37只眼(40.66%);术后3月裸眼视力≥0.2共85只眼(93.41%),≥0.5共42只眼(46.15%)。最佳矫正视力≥0.2共89只眼(97.80%),最佳矫正视力≥0.5共72只眼(79.12%)。术前散光度平均1.10D±0.78D,术后3月散光度平均1.25D±0.72D。术后散光度与术前散光度比较,差异无显著性(t=1.166,P=0.261)。无瞳孔严重变形、视网膜脱离、囊样黄斑水肿、瞳孔夹持、青光眼以及顽固性葡萄膜炎等并发症。结论低能量,高负压,低灌注,连续环形撕囊,双手劈核技术对于高度近视白内障患者更加安全有效。
简介:目的探讨数字化多媒体系统矫治训练对大龄儿童弱视的治疗效果。方法选取2013年1月至2016年1月我院门诊收治的大龄弱视患儿86例(128眼),作为研究对象。根据患儿治疗方案的差异将其分为观察组与对照组,对照组45例患儿接受常规综合治疗措施,观察组41例患儿接受数字化多媒体系统治疗,比较两组患儿治疗后双眼视功能变化及疗效。结果观察组患儿治疗后总有效率明显高于对照组,并且观察组患者立体视改善率明显高于对照组,P〈0.05,差异具有统计学意义。结论对大龄弱视患儿采取数字化多媒体系统治疗可有效改善患儿弱视症状,提高患儿双眼视功能,缩短患儿视功能障碍治疗时间,具有临床应用及推广价值。
简介:目的分析个性化角膜切口对白内障术后角膜散光及裸眼视力的影响。方法90例(106眼)白内障患者分为2组,试验组选择位于角膜最大屈光度径线上透明角膜切口,对照组选择11:00处的透明角膜切口,行白内障超声乳化人工晶状体植入术。术前及术后1周、1个月、3个月分别检测患者角膜散光及视力情况。结果术后1个月和3个月试验组裸眼视力分别为(4.9±0.15)、(5.0±0.15),显著优于对照组的(4.8±0.18)、(4.8±0.20),差异有统计学意义(P〈0.05)。术后1个月和3个月试验组角膜散光度分别为(0.78±0.39)、(0.79±0.40),明显低于对照组的(1.53±0.32)、(1.52±0.28),差异有统计学意义(P〈0.05)。结论白内障患者术前大多存在〈1.5D的角膜散光。采用个性化角膜切口可降低白内障手术角膜源性散光,术后视力恢复好,是一种简便、可行的手术切口。(中国眼耳鼻喉科杂志,2013,13:168—169,172)
简介:目的:通过对Q值调整非球面切削与标准化LASIK术后视觉质量的观察来分析Q值引导个性化切削技术的临床效果。方法:对2008-01/05等效球镜低于-12.00D的46例88眼进行非球面切削或标准化LASIK术后进行随访,按术前屈光度数将其分为A组(〈-6.00D)和B组(-6.00~-12.00D)两组,对比各组非球面切削与标准化LASIK术后1mo裸眼视力、Q值、夜间眩光、夜间视物质量及满意率(后3者采取问卷调查)。结果:A、B组内非球面切削与标准化LASIK术后裸眼视力差异无统计学意义(t=1.18,P〉0.05;t=0.62,P〉0.05);A、B组内非球面切削与标准化LASIK术后Q值差异无统计学意义(t=-0.93,P〉0.05;t=-0.372,P〉0.05);A组内非球面切削与标准化LASIK术后眩光、夜间视物质量差异无统计学意义(眩光:χ^2=2.397,P>0.05;夜间视物质量:χ2=1.263,P〉0.05);B组内非球面切削与标准化LASIK术后眩光、夜间视物质量差异有统计学意义(眩光:χ^2=10.85,P〈0.01;夜间视物质量:χ^2=10.85,P〈0.01);术后效果满意率达到98%。结论:非球面切削能明显改善-6.00D以上的术后主观视觉质量。
简介:目的:探讨规模化白内障手术中高龄及其伴全身疾病患者安全性。方法:回顾性分析"爱心光明行"活动中高龄及其伴全身疾病患者的临床资料。结果:本组高龄伴全身疾病患者213例(90.6%),其中循环系统疾病、代谢性疾病、呼吸系统疾病分别占65.1%,13.6%和11.1%。术前因首次全身疾病评估暂缓手术25例(10.6%),经有效治疗后手术。手术脱残率95.4%,脱盲率84.2%,12例视力〈0.1患者眼底检查均有不同程度的眼底病变。结论:加强术前综合因素评估,充分治疗全身疾病,严格掌握手术适应证,术中监护,操作轻巧,手术时间10~15min,是保证规模化白内障手术中高龄或伴全身疾病患者安全性的有效措施。
简介:目的对临床可疑青光眼患者进行长期的偏振激光扫描仪联合个体化角膜补偿技术(scanninglaserpolarimetrywithvariablecornealcompensation,GDxVCC)随访,分析GDxVCC对该类患者的诊断价值。方法选取门诊可疑青光眼的眼底检查视乳头杯/盘比(C/D)≥0.4,或双眼不对称且C/D差值〉10.2,静态视野检查结果正常患者68例,随访前后均用GDxVCC检查(采用相同的角膜补偿值)。如双跟C/D值相同,随机选取1眼,如C/D值不同,则选取C/D值大的1眼,对结果进行t检验统计学分析。结果随访时间6~30个月,平均(12.5±7.0)个月,眼底C/D值为0.57±0.17。随访前后GDxVCC检查:椭圆平均值分别为50.33±7.72和49.66±8.12,上方平均值为58.72±13.56和58.18±12.01,下方平均值为60.71±11.31和59.13±11.95,神经纤维指数为30.85±19.62和33.03±21.22,差异无统计学意义,但从绝对数值上,椭圆平均值、上方平均值和下方平均值变小,神经纤维指数变大。其中7例(10.3%)诊断为青光眼,21例(30.9%)排除青光眼,40例(58.8%)仍需进一步随访。结论对临床怀疑青光眼的患者应长期进行随访,GDxVCC随访对青光眼的诊断有一定的价值。(中国眼耳鼻喉科杂志,2009,9:92—94)
简介:AIM:ToIntroduceanewspecializedvisualacuitychartforamblyopicchildrenaged3-5yearsoldanditsclinicalapplications.METHODS:ThenewvisualacuitychartandnotationsweredesignedbasedonWeber-Fechnerlaw.Theoptotypeswereredagainstawhitebackgroundandwerespeciallyshapedfourbasicgeometricsymbols:circle,square,triangle,andcross.Aregulargeometricprogressionoftheoptotypesizesanddistributionwasemployedtoarrangein14lines.Theprogressionrateoftheoptotypesizebetweentwolineswas1.2589andthetestingdistancewas3m.VisualacuityscorecouldberecordedaslogMARnotationordecimalnotation.Agestratifieddiagnosticcriteriaforamblyopiaestablishedbyconsensusstatementondiagnosisofamblyopia(2011)amongmembersoftheStrabismusandPediatricOphthalmologyGroup,OphthalmologySociety,ChineseMedicalAssociation(SPOGOSCMA)wereillustratedinthenewvisualacuitychart.RESULTS:Whenassessingvisualacuityinchildrenaged3-5yearsold,thisnewvisualacuitychartthatconsistsoffoursymmetricalshapes(triangle,square,cross,andcircle)overcameaninabilitytorecognizethelettersofthealphabetanddifficultiesindesignatingthedirectionofblackabstractsymbolssuchasthetumbling’E’orLandolt’C’,whichthesubjectswerepronetoloseinterestin.Thevisualacuityscoremayberecordedindifferentnotations:decimalacuityandlogMAR.Thesetwonotationscanbeeasilyconvertedeachotherintheneweyechart.Themeasurementsofthisnewchartnotonlyshowedasignificantcorrelationandagoodconsistencywiththeinternationalstandardlogarithmicvisualacuitychart(r=0.932,P<0.01),butalsoindicatedahightest-retestreliability(89%ofretestscoreswerewithin0.1logMARunitsoftheinitialtestscore).CONCLUSION:Theresultsofthisstudysupportthevalidityandreliabilityofdistancevisualacuitymeasurementsusingtheneweyechartinchildrenaged3to5yearsoverawiderangeofvisualacuities,andtheneweyechartisgreatforearl