简介:钻爆法隧道穿越新建既有双连拱隧道结构,下穿隧道为大跨度隧道,高度大、埋深较深,且在穿越既有隧道时,不能影响其安全运营和造成结构破坏,施工难度大、风险高.采用有限元软件Midas GTS NX对钻爆法隧道下穿既有隧道的变形和受力情况进行数值模拟计算,并研究了下穿施工前对上方隧道间地层采用大管棚和锚杆联合加固产生的效果.研究表明:未加固时,施工侧隧道结构的沉降要大于另一侧,呈现出"一峰二谷"变形形状,既有隧道上下部极易发生结构破坏.采用大管棚及锚杆联合加固,有效地转移了应力集中现象,降低了结构破坏风险,并且既有隧道沉降量仅为前者变化量的 1/1.83,在控制标准以内.Abstract:The drilling and blasting tunnel crosses the newly built existing double-arch tunnel structure.The subway is a large span tunnel,with a large height and deep burial,and when crossing the existing tunnel,it cannot affect its safe operation and structural damage,the construction is difficult.A numerical simulation was carried out using the finite element software Midas GTS NX to calculate the deformation and stresses of a drilling and blasting tunnel underpassing an existing tunnel,and to study the effect of the combined reinforcement of the inter-tunnel strata above using large pipe sheds and anchors before the underpass construction.Studies have shown that the settlement of the tunnel structure on the co..
简介:【摘 要】 文章旨在通过对KDF2滤棒成型机高压喷嘴行程和气压的调整,减少爆珠滤棒生产过程中由于爆珠位置发生变化导致的轴向偏移频次,从而提升爆珠滤棒内爆珠轴向位置合格率。在爆珠滤棒生产过程中机台操作人员将“爆珠在滤棒内轴向位置严重偏移”这一问题反映至车间,通过对爆珠轴向位置偏移问题的原因进行试验与分析,表明高压喷嘴行程和气压是导致这一问题的直接原因,进而从人、机、料、法、环、测6 个方面导致爆珠轴向偏移问题的因素进行全面分析。结果表明人,机、料、环四个方面8条末端因素(人:操作不规范;机:投料装置运行不稳定、传动部件磨损、置珠盘正压不合理、烟舌高度不合理;料:爆珠粒径不符合工艺标准、丝束来料不合格;环:现场温湿度不符合工艺标准)为非要因,并最终确定以调整高压喷嘴行程和气压为切入点提升爆珠滤棒内爆珠轴向位置合格率。在此基础上,找出并验证高压喷嘴行程和气压的最佳值,验证结果表明高压喷嘴最佳的行程值和气压值可以提升爆珠轴向位置合格率。
简介:摘要:本文以室内可燃物为控制体进行能量守恒分析,在对火焰模型和烟气模型进行一定简化的基础上建立能量守恒方程,运用 火模型建立温度关于时间的非线性理论模型,通过火焰、烟气和壁面与可燃物之间的辐射换热和几何关系得出可燃物所获得的有效辐射热通量 ,建立当火源位于房间墙角处时轰燃时间与火源高度、房间尺寸、火源尺寸、火焰温度、烟气温度和壁面温度之间的物理辐射模型,最后对各个主要影响参量进行了相关性理论分析,当其余变量不变时,火源高度h与室内轰燃的发生的时间τ呈正相关关系。